Product Description
Machine Test System 0.3
Technical Specification
Equipment set for recording the characteristicsof electrical machines of the 300 Watt class,consisting of:
1.) Cradle-type three-phase asynchronous machine
2.) Control unit
Cradle-type three-phase asynchronousmachinewith squirrel-cage rotor and integrated torquepick-up and integrated incremental tacho. This specially-designed machine is equippedwith sufficient power and torque reserves to
brake up to standstill or drive any of the machines contained in the electrical machinesystem, power class 0.3 kW. Torque measurement is performed using strain gaugesmounted on a very durable, highly elastic stainless steel bending bar with fullyintegrated electronics. Overload protection is performed by monitoring with thermal circuitbreakers; power supply is carried out by the control unit via a permanently connected cablewith a round 7-pin connector plug. Transmission of the measured signal values isperformed using a fix D-sub 25 connection cable.
Torque: max. ± 9.9 Nm
Speed: max. ± 5,000 min-1
Control unit equipped with microcontroller andintegrated frequency converter capable ofsupplying the power and controlling the three-phase pendulum machine and displayingthe speed and torque measurement values. Connection to the PC is also displayed.The recording of the characteristics is performed point-by-point or automatically eithermanually or with the PC in all four quadrants ofthe speed/torque plane.
-Automatic digital speed control:
-5000 min-1...0...+5000 min-1
-Automatic digital torque control: ± 9.9 Nm
-Automatic recording of run-up and load
characteristics
-Load simulation: flywheel, lift drive (M = const.), fan drive (M~ kn2) free
adjustable, winding drive (M~k/n) freeadjustablefree recording characteristic relating to the user specification (Mi=ni)
-External control: -10 V...+10 V
-Seven segment display, 25 mm high, for speed: 4-digit, torque: 3 digit
parallel operation with software is possible
-Temperature monitoring: machine under test, pendulum machine, control unit
-Shaft guard observation: system stop with protection for unintended system start
-Four quadrant display with LEDs for operating mode of the machine under test
-Adjustable torque limiting (overloadprotection) and stop speed (for automatic
characteristic recording)
-RMS measuring: three inputs for voltage measuring (Umax=600 V AC/DC), one input for current measuring(Imax=10 A AC/DC), all frequency converter suitable
-USB for connection to PC for transmission of measured values and remote control via software
-Highest safety standard:
-Leakage current < 5 mA
Mains connection: 230 V, 47...62 Hz, 2 kW,with mains connection cable and earthing-pinplug